Banner CVZLBanner CVZL01Banner CVZL02

Climate test chamber

Climate test chambers simulate the environmental conditions, such as heat, cold and humidity or combination of these. Some devices also allow using of the sunlight xenon lamp radiation simulation. In these tests are verified the effects of the environment and its changes on the mechanical properties of the material or the function of products itself. Climate test chambers are used for tests of the products from the electrotechnical, engineering or automotive industry..

Technical standards:

EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30, EN 60068-2-78, EN 60068-2-38 
ISO 16750-4, PV 1200, PV 2005, PR 303, PR 308, TL 934, VW 80101 


 

 

 

 

Technical parameters:

Climate test chamber 10 m³

Test space volume cca 10 m3
Test space dimensions 2000 x 2000 x 2500 mm (w x d x h)
Temperature range - 50°C až +120°C
Humidity range 10% až 95% RH
Temperature change rate heating/cooling K/min 2/2
Special function PV1200, PV2005

Climate test chamber 3,4 m³

Test space volume cca  3,4 m3
Test space dimensions 1995 x 1150 x 1510 mm (w x d x h)
Temperature range - 72°C až +150°C
Humidity range 10% až 95% RH
Temperature change rate heating/cooling K/min 2/2
Special function PV1200, PV2005

Climate test chamber 2 m³

Test space volume cca 2 m3
Test space dimensions 950 x 2150 x 1050 mm (w x d x h)
Temperature range - 45°C až +180°C
Humidity range 10% až 98% RH
Temperature change rate heating/cooling K/min 3/2

Climate test chamber 1 m³

Test space volume cca 1 m3
Test space dimensions 1100 x 950 x 950 mm (w x d x h)
Temperature range - 72°C až +150°C
Humidity range 10% až 98% RH
Temperature change rate heating/cooling K/min 4/2,5
Zvláštní funkce PV1200, PV2005

Climate test chamber 0,6 m³

Test space volume cca 680 l
Test space dimensions 800 x 800 x 950 mm (w x d x h)
Temperature range - 72°C až +180°C; external box -55 až +150°C
Humidity range 10% až 98% RH; external box 10% až 80% RH
Temperature change rate heating/cooling K/min 4/2,5; external box 1/1
Special function PV1200, PV2005, external box connectivity

Climate test chamber 1 m³ with solar simulation

Test space volume cca 1 m3
Test space dimensions 1100 x 950 x 950 mm (w x d x h)
Temperature range

- 40°C až +120°C without radiation

-20°C až +100°C with radiation

Humidity range

10% až 90% RH without radiation

10% až 80% RH with radiation

Temperature change rate heating/cooling K/min 4/2,5
Special function Xenon lamp simulation 4,5 kW
Irradiance intensity 800-1200 W/m2
Radiation spectrum  208-3000 nm
Exposed area 5600 cm2

Temperature shock test chamber 120 l

Test space volume cca 120 l
Test space dimensions 500 x 400 x 630 mm (w x d x h)
Temperature range

+ 50°C až +200°C hot chamber

-80°C až +70°C cold chamber

Temperature change rate heating/cooling K/min

14 hot chamber

6,3 cold chamber

Special function shock change of temperature

Temperature test chamber 240 l

Test space volume cca 240 l
Test space dimensions 800 x 500 x 600 mm (w x d x h)
Temperature range -+5°C až +300°C
Temperature change rate heating/cooling K/min

na 70°C za 12 min

na 150°C za 27 min

¨na 300°C za 50 min

VYRTYCH a.s. | CENTRE OF DEVELOPMENT AND TEST LABORATORIES
Březno 317, 294 06  Březno, Czech Republic | tel. +420 326 397 610 | e-mail: laboratory@vyrtych.cz